Railway Cables | ||||||||||||
0.6/1KV Single Core Dual Wall Traction Cables
Application
Single Core power and control cable designed for protected, fi xed installation inside and outside railway vehicles for connecting fi xed and moving parts
Standards
● BS 6853 -1a
● DIN 5510-1 1-4
● NFF 16-101 F0
Construction
Conductors
Circular Class 5 stranded plain or tinned copper to BS EN 60228: 2005 / BS 6360.
Insulation 1
Electron beam crosslinkable thin wall LSZH compound.
Insulation 2
Electron beam crosslinkable thin wall LSZH compound.
Optional
FRA-DW-1S (Sheathed); FRA-DW-1S-OS (Screened & Sheathed);
FRA-DW-1SU-FR (Fire resistant & Unsheathed)
Electrical Characteristics at 20℃
|
Mechanical and Thermal Properties
Minimum Bending Radius:3×OD (OD<12mm); 4×OD (OD>12mm)
Temperature Range:-40℃ to +120℃
Dimensions And Weight
Cable Code |
No. of cores& Nominal Conductor Cross Sectional Area No.×mm² |
Nominal Diameter of Strands No/mm |
Nominal Insulation Thickness mm |
Nominal Overall Diameter mm |
Nominal Weight kg/km |
FRA-DW-1SU-1G0.5 |
1×0.5 |
19/0.18 |
0.2 |
1.3 |
5.5 |
FRA-DW-1SU-1G0.6 |
1×0.6 |
19/0.20 |
0.2 |
1.39 |
6.5 |
FRA-DW-1SU-1G0.75 |
1×0.75 |
19/0.22 |
0.2 |
1.52 |
8 |
FRA-DW-1SU-1G1 |
1×1.0 |
19/0.26 |
0.2 |
1.67 |
10 |
FRA-DW-1SU-1G1.2 |
1×1.2 |
19/0.28 |
0.2 |
1.83 |
12 |
FRA-DW-1SU-1G1.5 |
1×1.5 |
19/0.30 |
0.3 |
2.04 |
15 |
FRA-DW-1SU-1G2 |
1×2.0 |
37/0.25 |
0.3 |
2.29 |
19 |
FRA-DW-1SU-1G2.5 |
1×2.5 |
19/0.40 |
0.3 |
2.54 |
24 |
FRA-DW-1SU-1G3 |
1×3.0 |
37/0.32 |
0.3 |
2.78 |
29 |
FRA-DW-1SU-1G4 |
1×4.0 |
56/0.30 |
0.4 |
3.21 |
39 |